How to Choose a Photocatalytic Activity Evaluation System? Online Gas Chromatography vs Offline Sampling | Perfectlight

1. Two Evaluation Routes

Offline sampling is the classic approach: manually take gas and send it to the chromatograph after a reaction period. The advantage is simple equipment; the disadvantages are intermittent operation, easy missing of turning points, and large human error. Online gas chromatography (such as the μGAS1001 or the Labsolar-6A All-Glass Automatic Online Micro-Gas Analysis System) automatically outputs data continuously, suitable for long-term kinetics and high-throughput screening.

2. Comparison Across Three Dimensions

DimensionOffline samplingOnline gas chromatography
Time resolutionLow (per sample)High (per cycle)
RepeatabilityAffected by human factorsProgrammatic, stable
Suitable scenarioSingle-point verificationKinetics, screening

3. Cooperation with Multi-Channel Platforms

When using the PCX-50C Discover Multi-Channel Photocatalytic Reaction System for catalyst screening, offline sampling alone severely slows the pace; an online solution can feed gases from multiple channels into the same chromatograph in time-sharing, enabling high-throughput reading.

4. Selection Advice

  • Only doing principle verification on a limited budget: start with offline sampling;
  • Doing stability curves, AQY, or catalyst-library screening: prioritize the μGAS1001 online system;
  • Regardless of route, calibrate light intensity at the sample position with the PL-MW2000 High-Intensity Light Power Meter.

Free consultation: Not sure whether to go online or offline? Tell us your screening throughput and experimental cycle, and Perfectlight will calculate the return on investment for you and configure the μGAS1001 or PCX-50C.

Tel: 400-1161-365 / 010-62128921 Perfectlight Official Website

Related Products & Resources

Frequently Asked Questions (FAQ)

How to choose between online and offline?

Use offline for single-point verification; prioritize online gas chromatography for stability curves, AQY, and catalyst-library screening.

Is online mandatory for multi-channel screening?

When the PCX-50C multi-channel does high-throughput screening, offline sampling severely slows the pace; an online solution matches better.

Must light intensity be calibrated in either case?

Yes. Light intensity should be calibrated at the real sample position with the PL-MW2000; otherwise rates are not comparable.

This article does not constitute a performance commitment; specific technical parameters are subject to the actual product documentation and mutual confirmation.