Powder recovery loses 2–15 % of the catalyst per cycle, and 5 % loss per run reads as 23 % deactivation after five runs. Centrifuge at 8,000 × g for 10 min or filter through 0.22 µm, dry at 60 °C under vacuum, and close the mass balance within ±5 % before quoting any reuse number.
A degradation test usually starts with 100 mg of TiO2 in 250 mL at 0.4 g L−1. If each recovery step retains 95 % of the solid, the reactor holds 95.0, 90.3, 85.7, 81.5 and 77.4 mg across five cycles. Reported as a rate per reactor, that is a 23 % decline with no chemistry involved. Reported as a rate per gram of recovered catalyst, the same data are flat — and only the second number is a statement about the material.
The error is easy to make because the loss is invisible: fines pass a membrane, a decant drags a cloudy supernatant, and a little stays on the flask wall. Each path costs a few percent, never enough to notice in one run, always enough to invent a deactivation curve over five.
| Method | Typical recovery, 25 nm TiO2 | Time per 250 mL | Main risk |
|---|---|---|---|
| Vacuum filtration, 0.45 µm | 85–92 % | 5–10 min | Fines pass; membrane blinds |
| Vacuum filtration, 0.22 µm | 92–96 % | 10–20 min | Slow, needs a filter aid for slurries |
| Membrane, 0.1 µm | 95–98 % | 20–40 min | Adsorptive loss on the polymer |
| Centrifuge, 8,000 × g, 10 min | 95–98 % | 20 min incl. decant | Colloidal fraction stays suspended |
| Centrifuge, 15,000 × g, 20 min | 97–99 % | 30 min | Hard pellet, difficult to redisperse |
| Ultrafiltration, 50 kDa | 97–99 % | 30–60 min | Concentration polarisation, fouling |
| Rotary evaporation to dryness | 98–99 % | 40–60 min | Dissolved salts and sacrificial agent concentrate in the solid |
Recovery figures are for anatase with a 20–50 nm primary particle size, dispersed by 10 min of 40 kHz ultrasonication at 100 W before separation. A Degussa-type fumed oxide behaves differently: its 25 nm primary particles form 100–500 nm aggregates, which sediment readily but redisperse poorly, so a centrifuge recovers more and revives less.
Weigh before, not after. Record the dry mass charged, and confirm it by ICP-OES for titanium or by TOC for a carbon nitride, because a hygroscopic powder can be 3–8 % water by weight on a wet day. Dry a reference aliquot at 60 °C under vacuum for 12 h to constant weight and use that as the charged mass.
Sample before you separate. Withdraw the aliquot for GC or HPLC first, then recover the whole batch. Filtering first and sampling the filtrate changes both the volume and the solid loading, and the two effects are hard to unscramble afterwards.
Wash twice, with the right liquid. Two 20 mL water washes remove residual substrate and buffer. If the run used TEOA or a sulfide system, add one wash with 0.1 M NaOH followed by water to pH 7, otherwise adsorbed sulfur or amine keeps suppressing activity in the next cycle and gets blamed on the catalyst.
Dry to constant weight, then weigh on the same balance. 60 °C under vacuum for 12 h, cooled in a desiccator, weighed to 0.1 mg. Then compute recovery as mrecovered / mcharged. If that number is below 95 %, correct the rate before plotting it as a reuse series.
Oven drying at 105 °C in air is fast and is the usual reason a recovered catalyst looks deactivated. Held at that temperature for hours, hydrated surface layers condense, adjacent particles sinter at their contacts, and BET area falls by 10–30 % for a high-area anatase. The loss is then attributed to photocatalysis rather than to the drying step. Vacuum at 60 °C removes bulk water without driving that condensation.
Drying also removes the surface hydroxyls that carry the hole-transfer step. A sample dried hard and measured dry can be 15–25 % slower in the first re-run than the same sample re-wetted and equilibrated overnight in the reaction medium. Equilibrate before measuring, not after.
Redisperse by ultrasonication for 10 min at 40 kHz and 100 W, then confirm the particle size by dynamic light scattering against the fresh batch. Keep the catalyst concentration constant in mg L−1 rather than keeping the recovered mass constant, otherwise a 5 % loss quietly becomes a 5 % lower loading and a 5 % lower rate.
Measure BET area on the recovered solid and report the rate per gram and per square metre. If the per-area rate holds and the per-gram rate falls, the change is agglomeration, not chemical deactivation; if both fall, look for deposited metal, adsorbed intermediates or a phase change by XRD. Also run ICP on the filtrate: dissolved titanium above 1 ppm means the recovery number is not the only thing that is wrong.
Centrifuge at 8,000 × g for 10 min, decant, and centrifuge the supernatant once more at 15,000 × g to catch the colloidal fraction. Two-stage centrifugation typically recovers 97–99 % of a 25 nm anatase, against 85–92 % for a single pass through a 0.45 µm membrane.
Not chemically, but the pellet can be hard to redisperse. Above about 15,000 × g the cake compacts and 10 min of sonication may not restore the original aggregate size, which lowers the measured rate in the next cycle. Use the lowest g-force that clears the supernatant within 10 min.
Most often because 7 % of the powder was lost per cycle and the rate was normalised per reactor. Check the recovery figures first, then BET area, then the filtrate for dissolved metal. A genuine chemical deactivation usually shows a larger drop in the first cycle than in later ones, while mass loss is linear.
Within ±5 % of the charged mass per cycle, and within ±10 % cumulatively over five cycles. Anything wider should be reported as a recovery yield alongside the activity, so a reader can separate catalyst loss from catalyst deactivation.